Hyundai Equus: Specifications
| Specifications |
| Items | Specification |
| Air spring volume at design position | 1.78x |
| Maximum other bellow diameter | 118 mm |
| Burst pressure | 31.5 bar |
| Minimum operating temperature | -40°C |
| Maximum operating temperature | 80°C |
| Items | Specification |
| Operation voltage | 9 ~ 15 VDC |
| Max. perm. Current | 35 A Min |
| Lower operation temperature | -40°C |
| Upper operation temperature | 70°C |
| Storage Temperature | -40°C ~ 90°C |
| Items | Specification |
| Operation voltage | 9 ~ 15 VDC |
| Lower operation temperature | -40°C |
| Upper operation temperature | 70°C |
| Storage Temperature | -40°C ~ 90°C |
| Items | Specification |
| Required supply voltage | 5 VDC 5% |
| Operation voltage | 5 VDC 10% |
| Maximum allowed voltage range | 20 V |
| Storage Temperature | -40°C ~ 90°C |
| Items | Specification |
| Operating pressure | 16.5 bar |
| Burst pressure | 40 bar min |
| Air tank volume | 5.2 x |
| Items | Specification |
| Rated Voltage | 12 V DC |
| Operating Voltage | 10 ~ 16 V DC |
| Operation Temperature | -40°C ~ 75°C |
| Storage Temperature | -40°C ~ 90°C |
| Item | Tightening torque (kgf.m) | ||
| N.m | kgf.m | lb-ft | |
| Reservoir tank to crash box | 17.0 ~ 26.0 | 1.7 ~ 2.6 | 12.0 ~ 19.0 |
| Reservoir tank to frame housing | 20.0 ~ 30.0 | 2.0 ~ 3.0 | 14.0 ~ 22.0 |
| Front height sensor to frame | 17.0 ~ 26.0 | 1.7 ~ 2.6 | 12.0 ~ 19.0 |
| Front height sensor to lateral arm | 17.0 ~ 26.0 | 1.7 ~ 2.6 | 12.0 ~ 19.0 |
| Solenoid valve to bracket | 8.0 ~ 12.0 | 0.8 ~ 1.2 | 6.0 ~ 9.0 |
| Compressor to bracket | 8.0 ~ 12.0 | 0.8 ~ 1.2 | 6.0 ~ 9.0 |
| G-sensor to frame | 4.0 ~ 6.0 | 0.4 ~ 0.6 | 3.0 ~ 4.0 |
| Compressor & bracket to frame crash box | 35.0 ~ 55.0 | 3.5 ~ 5.5 | 25.0 ~ 40.0 |
| Air filter to frame | 4.0 ~ 6.0 | 0.4 ~ 0.6 | 3.0 ~ 4.0 |
| Front height sensor to frame | 4.0 ~ 6.0 | 0.4 ~ 0.6 | 3.0 ~ 4.0 |
| Feeling valve mounting bracket to frame | 17.0 ~ 26.0 | 1.7 ~ 2.6 | 12.0 ~ 19.0 |
Components and Components LocationCurtain Airbag (CAB) Module Repair procedures
Removal
1.
Disconnect the battery negative cable and wait for at least 3 minutes before beginning work.
2.
Remove the roof trim assembly.
(Refer to Body - "Roof Trim Assembly")
3.
Disconn ...
Compressor oil Repair procedures
Oil Specification
1.
The HFC-134a system requires synthetic (PAG) compressor oil
whereas the R-12 system requires mineral compressor oil. The two oils
must never be mixed.
2.
Compressor (P ...
Ambient Temperature Sensor Description and Operation
Description
The ambient temperature sensor is located at the front of the
condenser and detects ambient air temperature. It is a negative type
thermistor; resistance will increase with lower te ...