Hyundai Equus: Repair procedures
| Inspection |
| 1. |
After disconnecting the vapor hose from the PCV valve, remove the PCV valve. |
| 2. |
Reconnect the PCV valve to the vapor hose. |
| 3. |
Run the engine at idle, and put a finger on the open end of
the PCV valve and make sure that intake manifold vacuum can be felt.
|
| 4. |
If the vacuum is not felt, clean or replace the vapor hose. |
Schematic Diagrams
Positive Crankcase Ventilation (PCV) Valve Description and OperationHeater Control Unit Repair procedures
Replacement
1.
Disconnect the negative (-) battery terminal.
2.
Remove the cowl side trim.
(Refer to Body - "Cowl Side Trim")
3.
To remove the crash pad under cover [RH] (A), press both ...
Passenger Airbag (PAB) Module Repair procedures
Removal
1.
Disconnect the battery negative cable and wait for at least three minutes before beginning work.
2.
Remove the glove box housing.
(Refer to Body - "Glove Box Housing")
3.
Disc ...
Rear Disc Brake Components and Components Location
Components
1. Guide rod bolt2. Bleed screw3. Caliper body4. Caliper bracket5. Inner pad shim6. Brake pad7. Pad retainer
...