Hyundai Equus: Fuel Tank Pressure Sensor (FTPS) Repair procedures - Engine Control System - Engine Control/Fuel System - Hyundai Equus VI 2009-2026 Service ManualHyundai Equus: Fuel Tank Pressure Sensor (FTPS) Repair procedures

Inspection
1.
Connect the GDS on the Data Link Connector (DLC).
2.
Measure the output voltage of the FTPS.

Specification: Refer to "Specification"

Removal
1.
Turn the ignition switch OFF and disconnect the battery negative (-) cable.
2.
Remove the fuel pump service cover (A).

3.
Disconnect the fuel tank pressure sensor connector (A).
4.
Remove the fuel tank pressure sensor after remove the installation botl (B).

Installation
   
•
Install the component with the specified torques.
•
Note that internal damage may occur when the component is dropped. In this case, use it after inspecting.
   
•
Insert the sensor in the installation hole and be careful not to damage when installation.
1.
Install in the reverse order of removal.
    Fuel Tank Pressure Sensor (FTPS) Schematic Diagrams
    Circuit Diagram ...

    Injector Description and Operation
    Description Based on information from various sensors, the ECM can calculate the fuel amount to be injected. The fuel injector is a solenoid-operated valve and the fuel injection amount is cont ...

    See also:

    Line Pressure Control Solenoid Vale Schematic Diagrams
    Circuit Diagram ...

    Purge Control Solenoid Valve (PCSV) Repair procedures
    Inspection 1. Turn the ignition switch OFF. 2. Disconnect the PCSV connector. 3. Measure resistance between the PCSV terminals 1 and 2. 4. Check that the resistance is within the speci ...

    TPMS Receiver Description and Operation
    Description 1. Mode (1) Virgin State A. The receiver as a sole part is shipped in this state. Replacement parts should therefore arrive in this state. B. In this state, there is no Auto-Lo ...