Hyundai Equus: Line Pressure Control Solenoid Vale Specifications
| Specifications |
| Control Pressure kpa (kgf/cmx, psi) | 0~500.14 (0~5.1,0~72.54) |
| Current value(mA) | 0~850 |
| Internal resistance(x) | 4.8~5.4 |
Line Pressure Control Solenoid Vale Description and Operation
Line Pressure Control Solenoid Vale Schematic Diagrams35R Clutch Control Solenoid Valve(35R/C_VFS) Repair procedures
Inspection
1.
Turn ignition switch OFF.
2.
Disconnect the E Module connector.
3.
Measure resistance between sensor signal terminal and sensor ground terminal.
4.
Check that the res ...
Instrument Cluster Repair procedures
Removal
1.
Disconnect the negative (-) battery terminal.
2.
Remove the cluster fascia panel after loosening the screws.
(Refer to Body - "Cluster Fascia Panel")
3.
Remove the cluster asse ...
Fuel Pump Motor Components and Components Location
Components
Pin NO.ItemDescription1Upper body3-phase coil power supply, fuel delivery, and sealing2Stator assemblyCreates an N pole and S pole flux to induce the rotor to turn.3rotor assemblyTorqu ...