Hyundai Equus: Description and Operation
| Warning Lamp Activation |
| Warning Lamp Behavior after Ignition On |
| 1. |
Active fault or historical fault counter is greater or equal to 10.
|
| 2. |
Normal or historical fault counter is less than 10.
|
| 3. |
When turning the ignition switch ON during variant coding
(EOL) mode, the airbag warning lamp is turned on and blinks at intervals
of 1 second till the coding is completed.
In case the variant coding is normally completed, the airbag
warning lamp is turned on for 6 seconds, and then turned off. Otherwise
the airbag warning lamp continuously blinks at intervals of 1 second.
When there is active fault in the airbag system or SRSCM
internal fault, the variant coding (EOL) cannot be completed. In this
case, do the variant coding (EOL) procedure again after troubleshooting
with the GDS. |
| 1. |
Loss of battery supply to the SRSCM : warning lamp is turned on continuously. |
| 2. |
Loss of internal operating voltage : warning lamp is turned on continuously. |
| 3. |
Loss of microprocessor operation : warning lamp is turned on continuously. |
| 4. |
SRSCM not connected : warning lamp is turned on continuously. |
| Occupant Status | Telltale Lamp | PAB |
| Empty | ON | Disabled |
| Child (Small Occupant) | ON | Disabled |
| Adult (Large Occupant) | OFF | Enabled |
| Defect | OFF | Enabled |

General Safety Information and Caution
Repair proceduresCamshaft Position Sensor (CMPS) Repair procedures
Inspection
1.
Check the signal waveform of the CMPS and CKPS using the GDS.
Specification: Refer to “Wave Form�
Removal
•
DON’T remove the camshaft pos ...
Binding arbitration (U.S.A only)
Any claim or dispute you may have related to your vehicle's warranty or the duties
contemplated under the warranty, including claims related to the refund or partial
refund of your vehicle' ...
Intake Actuator Repair procedures
Inspection
1.
Turn the ignition switch OFF.
2.
Disconnect the intake actuator connector.
3.
Verify that the intake actuator operates to the fresh position when connecting 12V to terminal 3 ...