Hyundai Equus: Specifications - General Information - Heating, Ventilation and Air Conditioning - Hyundai Equus VI 2009-2026 Service ManualHyundai Equus: Specifications

Specification
Air Conditioner
Item
Specification
Compressor
Type
7VSX18
Oil type & Capacity
PAG 120± 10cc (4.1±0.3oz.)
Pulley type
Around rubber damper
Displacement
180cc/rev
Condenser
Heat rejection
18,500 kcal/h
Expansion valve
Type
Block type
Refrigerant
Type
HFC-134a (R-134a)
Capacity
700 ± 25g (24.7 ± 0.88oz.)

Blower Unit
Item
Specification
Fresh and recirculation
Operating method
Actuator
Blower
Type
Sirocco
Speed step
Auto + 8 speed
Speed control
Power mosfet
Air filter
Type
Particle filter

Heater and Evaporator Unit
Item
Specification
Heater
Type
Pin & Tube type
Heating capacity
4,850 ± 5% kcal/hr
Mode operating method
Actuator
Temperature operating method
Actuator
Evaporator
Cooling capacity
4,500 ± 5% kcal/hr
Temperature control type
Evaporator temperature sensor
A/C ON/OFF
ON: 2.1 ± 0.5°C, (35.8 ± 32.9 °F)
OFF: 0.6 ± 0.5°C, (33.1 ± 32.9 °F)

Tightening Torques
Items
N.m
kgf.m
lb-ft
Compressor
19.6 ~ 33.3
2.0 ~ 3.4
14.5 ~ 24.6
Condenser - Discharge hose
3.9 ~ 5.9
0.4 ~ 0.6
2.9 ~ 4.3
Condenser - Liquid tube
Compressor - Discharge hose
6.9 ~ 8.8
0.7 ~ 0.9
5.1 ~ 6.5
Compressor - Suction hose
Expansion valve - Evaporator
8.8 ~ 13.7
0.9 ~ 1.4
6.5 ~ 10.1

    General Information
    ...

    Special Service Tools
    Special Service Tools Tool (Number and name)IllustrationUse09977-3R000Disc & hub assembly bolt removerRemoval and installation of disc & hub assembly bolt ...

    See also:

    Description and Operation
    Description In the state of IGN1 ON, when the multi function switch module detects auto light switch on, tail lamp relay output and head lamp low relay output are controlled according to the ve ...

    Interior care
    Interior general precautions Prevent chemicals such as perfume, cosmetic oil, sun cream, hand cleaner, and air freshener from contacting the interior parts because they may cause damage or discol ...

    4&OD Clutch Control Solenoid Valve Specifications
    Specifications Direct control VFS[4&OD/C] x Control type : Normal high type Control Pressure kpa (kgf/cmx, psi)0~1569.06 (0~16,0~227.57)Current value(mA)0~1100 Internal resistanc ...