Circuit Diagram |
Purge Control Solenoid Valve (PCSV) Description and Operation
Description
Purge Control Solenoid Valve (PCSV) is installed on the surge
tank and controls the passage between the canister and the intake
manifold. It is a solenoid valve and is open when the ...
Hazard Lamp Switch Repair procedures
Inspection
1.
Check "IPM" input/output specification of hazard lamp switch
using the GDS. If the specification is abnormal, replace the hazard
switch module.
2.
Select option "Input/output ...
ON/OFF Solenoid Valve Repair procedures
Inspection
1.
Turn ignition switch OFF.
2.
Disconnect the E Module connector.
3.
Measure resistance between sensor signal terminal and sensor ground terminal.
4.
Check that the res ...