General |
1. |
Basically, all measurements in this manual are taken with a tracking gauge. |
2. |
When a measuring tape is used, check to be sure there is no elongation, twisting or bending. |
3. |
For measuring dimensions, both projected dimension and actual-measurement dimension are used in this manual. |
Measurement method |
Projected dimensions |
1. |
These are the dimensions measured when the measurement
points are projected into the reference plane, and are the reference
dimensions used for body alterations. |
2. |
If the length of the tracking gauge probes are adjustable,
make the measurement by lengthening one probe by the amount equivalent
to the difference in height of the two surfaces. |
Actual-measurement dimensions |
1. |
These dimensions indicate the actual linear distance between
measurement points, and are the reference dimensions for use if a
tracking gauge is used for measurement. |
2. |
Measure by first adjusting both probes to the same length (A=A')
|
Measurement point |
1. |
Measurements should be taken at the hole center. |
Occupant classification system
Your vehicle is equipped with an occupant classification system in the front
passenger's seat.
The occupant classification system is designed to detect the presence of a properly-seated
f ...
Alternator Specifications
Specification
ItemSpecificationRated voltage13.5V , 180ASpeed in use1,000 ~ 18,000rpmVoltage regulatorIC Regulator built in type Regulator reform mode voltage (V) [COM terminal]13.85 ~ 14.85 (-35 ...
Electric Parking Brake (EPB) Repair procedures
Removal
1.
Release the parking brake by pushing the EPB switch.
2.
Turn ignition switch off and disconnect the battery (-) cable from the battery.
3.
Remove the canister service cover in ...