Specifications |
Items | Specification |
Air spring volume at design position | 1.78x |
Maximum other bellow diameter | 118 mm |
Burst pressure | 31.5 bar |
Minimum operating temperature | -40°C |
Maximum operating temperature | 80°C |
Items | Specification |
Operation voltage | 9 ~ 15 VDC |
Max. perm. Current | 35 A Min |
Lower operation temperature | -40°C |
Upper operation temperature | 70°C |
Storage Temperature | -40°C ~ 90°C |
Items | Specification |
Operation voltage | 9 ~ 15 VDC |
Lower operation temperature | -40°C |
Upper operation temperature | 70°C |
Storage Temperature | -40°C ~ 90°C |
Items | Specification |
Required supply voltage | 5 VDC 5% |
Operation voltage | 5 VDC 10% |
Maximum allowed voltage range | 20 V |
Storage Temperature | -40°C ~ 90°C |
Items | Specification |
Operating pressure | 16.5 bar |
Burst pressure | 40 bar min |
Air tank volume | 5.2 x |
Items | Specification |
Rated Voltage | 12 V DC |
Operating Voltage | 10 ~ 16 V DC |
Operation Temperature | -40°C ~ 75°C |
Storage Temperature | -40°C ~ 90°C |
Item | Tightening torque (kgf.m) | ||
N.m | kgf.m | lb-ft | |
Reservoir tank to crash box | 17.0 ~ 26.0 | 1.7 ~ 2.6 | 12.0 ~ 19.0 |
Reservoir tank to frame housing | 20.0 ~ 30.0 | 2.0 ~ 3.0 | 14.0 ~ 22.0 |
Front height sensor to frame | 17.0 ~ 26.0 | 1.7 ~ 2.6 | 12.0 ~ 19.0 |
Front height sensor to lateral arm | 17.0 ~ 26.0 | 1.7 ~ 2.6 | 12.0 ~ 19.0 |
Solenoid valve to bracket | 8.0 ~ 12.0 | 0.8 ~ 1.2 | 6.0 ~ 9.0 |
Compressor to bracket | 8.0 ~ 12.0 | 0.8 ~ 1.2 | 6.0 ~ 9.0 |
G-sensor to frame | 4.0 ~ 6.0 | 0.4 ~ 0.6 | 3.0 ~ 4.0 |
Compressor & bracket to frame crash box | 35.0 ~ 55.0 | 3.5 ~ 5.5 | 25.0 ~ 40.0 |
Air filter to frame | 4.0 ~ 6.0 | 0.4 ~ 0.6 | 3.0 ~ 4.0 |
Front height sensor to frame | 4.0 ~ 6.0 | 0.4 ~ 0.6 | 3.0 ~ 4.0 |
Feeling valve mounting bracket to frame | 17.0 ~ 26.0 | 1.7 ~ 2.6 | 12.0 ~ 19.0 |
Crash Pad Lower Panel Components and Components Location
Component Location
1. Crash pad lower panel
...
Repair procedures
Inspection
Initialization and diagnosis sequence by using diagnostic equipment
Below content summarize the procedure for A/S using Diagnostic equipment
Download Parameter
1.
Select "AFLS" menu ...
AVN Antenna Components and Components Location
Components
...