Specifications |
Item | Specification | |
Front/Rear parking assist system control unit | Rated voltage | DC 12V |
Operation range | 30~120 cm(11.8~47.2 in) | |
Operation voltage | DC 9V~16V | |
Operation current | Max. 300 mA | |
Operation temperature | -30~+80 °C | |
Operation frequency | 48 ± 5 KHz | |
Number of sensors | Front : 4EA(Left, Right, Center left, Center right) Rear : 4EA(Left, Right, Center left, Center right) |
Crankshaft Position Sensor (CKPS) Specifications
Specification
ItemSpecificationCoil Resistance (x)774 ~ 946 [20°C (68°F)]Air cap(mm)0.5 ~ 1.5
...
Description and Operation
Description
AbbreviationExplanationC_CANChassis Controller Area NetworkB_CANBody Controller Area NetworkMM_CANMulti media Controller Area NetworkSMKSmart Key UnitDDMDriver Door ModuleADMAssist Do ...
CVVT Oil Control Valve (OCV) Repair procedures
Inspection
1.
Turn the ignition switch OFF.
2.
Disconnect the OCV connector.
3.
Measure resistance between the OCV terminals 1 and 2.
4.
Check that the resistance is within the specifi ...