Hyundai Equus: 4&OD Clutch Control Solenoid Valve Specifications - Automatic Transmission Control System - Automatic Transmission System (SBC) - Hyundai Equus VI 2009-2025 Service ManualHyundai Equus: 4&OD Clutch Control Solenoid Valve Specifications

Specifications
Direct control VFS[4&OD/C]
x Control type : Normal high type
Control Pressure kpa (kgf/cmx, psi)
0~1569.06
(0~16,0~227.57)
Current value(mA)
0~1100
 Internal resistance(x)
5.0~5.6

    4&OD Clutch Control Solenoid Valve Description and Operation
    Description 4&OD Clutch control solenoid valve is attached to the valve body. This variable force solenoid valve directly controls the hydraulic pressure inside the 4&OD Clutch. ...

    4&OD Clutch Control Solenoid Valve Schematic Diagrams
    Circuit Diagram ...

    See also:

    Middle Speed Sensor Specifications
    Specifications x Type: Hall effect sensor x Specifications Operation condition (°C)°F ((-)40~150)) -40~302Air gap(mm)in.1.3(0.0512)Output voltage(V)High1.4Low0.7 ...