Hyundai Equus: 4&OD Clutch Control Solenoid Valve Specifications
| Specifications |
| Control Pressure kpa (kgf/cmx, psi) | 0~1569.06 (0~16,0~227.57) |
| Current value(mA) | 0~1100 |
| Internal resistance(x) | 5.0~5.6 |
4&OD Clutch Control Solenoid Valve Description and Operation
4&OD Clutch Control Solenoid Valve Schematic DiagramsCanister Close Valve (CCV) Description and Operation
Description
Canister Close Valve (CCV) is normally open and is installed
on the canister ventilation line. It seals evaporative emission control
system by shutting the canister from the atmosph ...
Fuel Line Repair procedures
Removal
1.
Turn ignition switch OFF and disconnect the negative (-)battery cable.
2.
Release the residual pressure in fuel line.
(Refer to Fuel Delivery System - "Release Residual Pressure in ...
Rear Variable Damper Description and Operation
Description
The rear variable damper consists of a damper and an upper
mounting bracket. This damper determines vehicle behavior through the