Hyundai Equus: Troubleshooting
| Troubleshooting |
| Problem Symptoms Table |
| Symptom | Suspected Area |
| No blower operation | 1. Blower fuse |
| 2. Blower relay | |
| 3. Blower motor | |
| 4. Power mosfet | |
| 5. Blower speed control switch | |
| 6. Wire harness | |
| No air temperature control | 1. Engine coolant capacity |
| 2. Heater control assembly | |
| No compressor operation | 1. Refrigerant capacity |
| 2. A/C fuse | |
| 3. Compressor | |
| 4. A/C pressure transducer | |
| 5. A/C switch | |
| 6. Evaporator temperature sensor | |
| 7. Wire harness | |
| Vented air not cold | 1. Refrigerant capacity |
| 2. Refrigerant pressure | |
| 3. Drive belt | |
| 4. Compressor | |
| 5. A/C pressure transducer | |
| 6. Evaporator temperature sensor | |
| 7. A/C switch | |
| 8. Heater control assembly | |
| 9. Wire harness | |
| Insufficient cooling | 1. Refrigerant capacity |
| 2. Drive belt | |
| 3. Compressor | |
| 4. Condenser | |
| 5. Expansion valve | |
| 6. Evaporator | |
| 7. Refrigerant lines | |
| 8. A/C pressure transducer | |
| 9. Heater control assembly | |
| No engine idle-up when A/C switch ON | 1. Engine ECM |
| 2. Wire harness | |
| No air inlet control | 1. Heater control assembly |
| No mode control | 1. Heater control assembly |
| 2. Mode actuator | |
| No cooling fan operation | 1. Cooling fan fuse |
| 2. Fan motor | |
| 3. Engine ECM | |
| 4. Wire harness |
Special Service ToolsHeater Control Unit Repair procedures
Replacement
1.
Disconnect the negative (-) battery terminal.
2.
Remove the cowl side trim.
(Refer to Body - "Cowl Side Trim")
3.
To remove the crash pad under cover [RH] (A), press both ...
Rear Differential Carrier Repair procedures
Replacement
1.
Drain off oil from Rear differential carrier.
2.
Remove the propeller shaft.
(Refer to Propeller Shaft Assembly - "Propeller Shaft")
3.
Remove the rear drive shaft.
(Re ...
Specifications
Specifications
Front air strut
ItemsSpecificationAir spring volume at design position1.78xMaximum other bellow diameter118 mmBurst pressure31.5 barMinimum operating temperature-40°CMaximum operat ...