Hyundai Equus: Purge Control Solenoid Valve (PCSV) Specifications - Engine Control System - Engine Control/Fuel System - Hyundai Equus VI 2009-2026 Service ManualHyundai Equus: Purge Control Solenoid Valve (PCSV) Specifications

Specification
Item
Specification
Coil Resistance (x)
14.0 ~ 18.0 [20°C(68°F)]

    Purge Control Solenoid Valve (PCSV) Description and Operation
    Description Purge Control Solenoid Valve (PCSV) is installed on the surge tank and controls the passage between the canister and the intake manifold. It is a solenoid valve and is open when the ...

    Purge Control Solenoid Valve (PCSV) Schematic Diagrams
    Circuit Diagram ...

    See also:

    Components and Components Location
    Components 1. Cowl side trim2. Front door scuff trim3. Center pillar lower trim4. Rear door scuff trim5. Rear pillar trim6. Rear wheel house trim7. Rear package tray trim 8. Front pillar trim ...

    Rear Assist Arm Repair procedures
    Removal 1. Remove the rear wheel and tire (A) from rear hub . Tightening torque: 88.3 ~ 107.9 N.m (9.0 ~ 11.0 kgf.m, 65.1 ~ 79.6 lb-ft)     • Be careful not to damage ...

    BlueLink Control Switch Components and Components Location
    Components ...