Hyundai Equus: Over Pressure Valve (OPV) Repair procedures
| Removal |
| 1. |
Turn the ignition switch OFF and disconnect the battery negative (-) cable. |
| 2. |
Release the residual pressure in fuel line.
(Refer to Fuel Delivery System -"Release Residual Pressure in Fuel Line") |
| 3. |
Remove the fuel pump.
(Refer to Fuel Delivery System - "Fuel Pump") |
| 4. |
Release the fixing hook, remove the over pressure valve (A) from the fuel filter.
|
| Installation |
| 1. |
Install in the reverse order of removal. |
Fuel Sender Assembly Repair procedures
Fuel Pump Control Module (FPCM) Description and OperationDescription and Operation
Description
Adaptive Front-lighting System (AFLS)
AFLS(Adaptive Front-lighting System)is a headlamp
orientation control system that takes into account both steering angle
and vehicle speed to ...
Troubleshooting
Troubleshooting
Ignition System
SymptomSuspect AreaRemedyEngine will not start or is hard to start (Cranks OK)Ignition lock switchInspect ignition lock switch, or replace as requiredIgnition c ...
Description and Operation
Description
Windshield deicer system prevent windshield wiper from
freezing in the winter season. It consists of deicer in the lower part
of windshield, switch and relay. Body control module re ...