Hyundai Equus: Purge Control Solenoid Valve (PCSV) Specifications
| Specification |
| Item | Specification |
| Coil Resistance (x) | 14.0 ~ 18.0 [20°C(68°F)] |
Purge Control Solenoid Valve (PCSV) Description and Operation
Purge Control Solenoid Valve (PCSV) Schematic DiagramsAUX jack Repair procedures
Removal
1.
Remove the floor console upper tray.
(Refer to Body - "Floor Console Assembly")
2.
Remove the center fascia lower tray.
(Refer to Body - "Center fascia pannel")
3.
Remove the ...
Warning type
The system will activate when:
1.The system is on
2.Vehicle speed is above 9.3 mph (15 km/h)
3.Other vehicles are detected in the rear side
If a vehicle is detected within the boundary of the ...
Specifications
Specifications
Front air strut
ItemsSpecificationAir spring volume at design position1.78xMaximum other bellow diameter118 mmBurst pressure31.5 barMinimum operating temperature-40°CMaximum operat ...