Hyundai Equus: Fuel Filler Door Release Actuator Repair procedures - Fuel Filler Door - Body Electrical System - Hyundai Equus VI 2009-2026 Service ManualHyundai Equus: Fuel Filler Door Release Actuator Repair procedures

Inspection
1.
Remove the trunk room left side trim.
2.
Open the fuel filler door and remove the housing.
(Refer to the BD group - "Exterior")
   
Do not reuse the fuel filler door housing.
3.
Remove the connector and bolts (2EA).

4.
Check for continuity between terminal No.1 and No.2. If there is no continuity replace the fuel filler door opener.

    Components and Components Location
    Component Location 1. Fuel filler door open switch2. Fuel filler door release actuator ...

    Fuel Filler Door Open Switch Repair procedures
    Inspection 1. Remove the front door trim panel. (Refer to BD group - "Front door") 2. Check the switch (A) for continuity between the terminals. 3. If the continuity is not as specified, ...

    See also:

    Fuel Pressure Control Valve Description and Operation
    Description Fuel Pressure Control Valve is installed on the high pressure fuel pump and controls fuel flow flowing into the injectors in accordance with the ECM signal calculated based on vario ...

    PGS Unit (Back & Blinde Unit) Repair procedures
    Removal 1. Disconnect the negative (-) battery terminal. 2. Remove the glove box housing (A). (Refer to Body - "Crach Pad") 3. Remove the glove box housing connector (A). 4. Remove t ...

    Trunk room lamp
    The trunk room lamp comes on when the trunk is opened. CAUTION The trunk room lamp comes on as long as the trunk lid opens. To prevent unnecessary charging system drain, close the trunk lid se ...